Heatherbrae bypass: driven-pile testing through more than 60 metres of ground
A June 2026 paper by WSP engineers Saman Zargarbashi and Alireza Foroughi documents the performance of open-ended steel tubular piles supporting the Windeyers Creek bridge on the Heatherbrae bypass.
The piles measured 1,150 mm and 1,250 mm in external diameter and extended more than 60 metres through layered ground.
The authors report:
- Different driving behaviour between neighbouring piles in broadly similar ground, associated with differences in soil plugging.
- Increased shaft resistance during restrike tests conducted four to eight days after installation.
- Reduced toe resistance in some piles terminating in siltstone.
- Cases where available hammer energy appeared insufficient to fully mobilise toe resistance during dynamic testing.
The study compares design predictions with PDA testing and CAPWAP analysis, documenting both the results and limitations of interpretation.
Original sourceRead the complete six-page paper ↗Published in the proceedings of the 21st ICSMGE, June 2026.